Background
If a cog, hook or ligature leg is too short, the bar can't be bent. The tables below show the shortest leg allowed for each bar size.
All measurements are in millimetres (mm).
Steps to follow
Choose a table
Use the Fitment Table for ligatures and fitments from N10 to N24.
Use the Standard Table for everything else. This includes ligatures and fitments N28 and larger.
Long shapes are an exception:
T-Shape
For any T-shape (closed ligature), where the length of any single element exceeds 1501 mm, the standard reinforcement bending requirement of a minimum 5 × bar diameter (5d) pin diameter shall apply.
LL-Shape
For any LL-shape, where A & C element exceeds 1501 mm, the standard reinforcement bending requirement of a minimum 5 × bar diameter (5d) pin diameter shall apply to dimension B.
U-Shape
For any U-shape, where A & C element exceeds 1501mm, the standard reinforcement bending requirement of a minimum 5 × bar diameter (5d) pin diameter shall apply to dimension B.
Check each leg
- Find the bar size in the table.
- Check that every cog, hook and ligature leg is at least the number shown.
If a leg is shorter, make it longer before the shape is released.
Standard Table
| Bar Diameter | Minimum Pin Size | Minimum Cog | Minimum Double Cog | Minimum Double Reverse Cog | Minimum Hook Length | Minimum Hook Height | Minimum Ligature |
|---|---|---|---|---|---|---|---|
| 5 x Diameter for Standard Reinforcement | |||||||
| N10 | 50 | 120 | 120 | 120 | 120 | 75 | 120 |
| N12 | 60 | 145 | 145 | 145 | 145 | 90 | 145 |
| N16 | 80 | 195 | 195 | 195 | 195 | 120 | 195 |
| N20 | 100 | 240 | 240 | 240 | 240 | 150 | 240 |
| N24 | 120 | 290 | 290 | 290 | 290 | 180 | 290 |
| N28 | 140 | 340 | 340 | 340 | 340 | 210 | 340 |
| N32 | 160 | 385 | 385 | 385 | 385 | 240 | 385 |
| N36 | 180 | 435 | 435 | 435 | 435 | 270 | 435 |
| N40 | 200 | 480 | 480 | 480 | 480 | 300 | 480 |
Fitment Table
| Bar Diameter | Minimum Pin Size | Minimum Cog | Minimum Double Cog | Minimum Double Reverse Cog | Minimum Hook Length | Minimum Hook Height | Minimum Ligature |
|---|---|---|---|---|---|---|---|
| 4 x Diameter for Fitment Reinforcement only | |||||||
| N10 | 40 | 110 | 110 | 120 | 110 | 65 | 110 |
| N12 | 48 | 135 | 135 | 145 | 135 | 80 | 135 |
| N16 | 64 | 180 | 180 | 195 | 180 | 105 | 180 |
| N20 | 80 | 220 | 220 | 240 | 220 | 130 | 220 |
| N24 | 100 | 265 | 265 | 290 | 265 | 160 | 265 |
| N28 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| N32 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| N36 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| N40 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
The Minimum Double Reverse Cog is the same in both tables. There is no shorter fitment version.
What the Columns Mean
- Bar Diameter: the bar size.
- Minimum Pin Size: the size of the pin the bar is bent around.
- Minimum Cog: a 90° bend at one end of the bar.
- Minimum Double Cog: a cog at both ends, pointing the same way.
- Minimum Double Reverse Cog: a cog at both ends, pointing opposite ways.
- Minimum Hook Length: the leg on a hook.
- Minimum Hook Height: the overall height of a hook.
- Minimum Ligature: the leg on a closed ligature.
Comments (0 comments)